EasyManua.ls Logo

Clear-Com LQ series - Page 59

Clear-Com LQ series
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
399G116 Rev D
Device type Which LQ
unit?
Port Function Supports
call
signaling?
Panel
data?
RTS 2-wire
equipment
LQ-2W2
LQ-R2W4
LQ-R2W4-4W4
N/A Yes, but
does not
pass call
signaling to
4-wire audio
routes.
No
HME DX210 LQ-4W2
LQ-R4W8
LQ-R2W4-4W4
LQ-2W2*
LQ-R2W4*
To panel
N/A
Yes No
Tempest 2400 LQ-4W2
LQ-R4W8
LQ-R2W4-4W4
LQ-2W2*
LQ-R2W4*
To panel
N/A
Yes No
FreeSpeak LQ-4W2
LQ-R4W8
LQ-R2W4-4W4
LQ-2W2*
LQ-R2W4*
To panel
N/A
Yes** No
V-Series panel
i-Series panel
LQ-4W2
LQ-R4W8
LQ-R2W4-4W4
To panel Yes Yes
*This connection is not preferred for optimum audio quality. LQ-4W2 is
recommended.
** On a FreeSpeak Base station, only ports 3 and 4 pass call signaling.
Table 1 Interconnection guidelines