• Prevents the ability of any of the LQ units to modify the name of any of the static
channel names.
• Prevents the distribution of device configuration changes throughout the Link-Group
resulting in the possibility of having an inconsistent view of that configuration
information depending on the perspective from which the device information is
retrieved.
14.13 Does the LQ-4W2 pass call signaling?
Yes, but only call signaling originating from Clear-Com equipment. Call signalling to
RTS equipment will be limited.
14.14 Can I link LQ-2W to an LQ-4W?
Yes, a 2-wire device can be linked to a 4-wire device.
14.15 Connectivity, including Web access to my LQ unit is
intermittent, even though I am accessing it from
within the same LAN.
The most probable cause for this is that an IP conflict exists. In this case, the IP
address used by the LQ unit is already in use by another device within your LAN.
The quickest and easiest way to check if this is the problem is to change the LQ
unit’s IP address to an address that is known to be available and observe if
connectivity to the unit is once again consistent.
LAN, WAN,
Internet
LQ 2W
LQ 4W