73
399G116 Rev D
15.1.6 Connectors
LQ Throw Down Units
2-wire (LQ-2W2) 4-wire (LQ-4W2)
2 x etherCON (F) : network
2 x 3 pin XLR-F: audio
4 x etherCON (F): 2 for network, 2 for
audio
LQ Rack Units
2-wire (LQ-R2W4) 4-wire (LQ-R4W8) Combined (LQ-
R2W4-4W4)
2 x etherCON (F) : network
4 x 3 pin XLR-F
4 x 3 pin XLR-M
2 x etherCON (F) : network
8 x etherCON RJ45 F
2 x etherCON (F) :
network
4 x etherCON RJ45 F
4 x 3-pin XLR-F
15.1.7 Power supply
LQ-R Rack Units LQ Throw Down Unit
Input: 100-240V, 47-63Hz, 0.58A max
Output: DC 12V, 2A, 60W max
Input: 100-240V, 47-63Hz, 0.58A max
Output: DC 12V, 2A, 24W max
2 x Plug-in adapter with sleeve locking
connector
US,UK, Europe, AUS and China sockets
included
1 x Plug-in adapter with sleeve locking
connector
US,UK, Europe, AUS and China sockets
included
15.1.8 Environmental
Operating temperature 32 - 104°F (0 - 40°C)
Storage temperature -67 - 158°F (-55 - 70°C)
Humidity 90% non-condensing
15.1.9 Dimensions and weight
LQ Throw Down Unit LQ-R Rack Unit
Dimensions 6.8w x1.79h x 8.45d
inches
(173 x 46 x 215 mm)
19w x1.79h x 8.8d
inches
(484 x 46 x 224 mm)
Weight 1.83lbs (.83kg) 4.29lbs (1.95kg)