EasyManua.ls Logo

ComAp InteliVision 8 User Manual

ComAp InteliVision 8
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Copyright © 2017 ComAp a.s.
Written by ComAp
Prague, Czech Republic
ComAp a.s., U Uranie 1612/14a,
170 00 Prague 7, Czech Republic
Tel: +420 246 012 111
E-mail: info@comap-control.com, www.comap-control.com
Global Guide
InteliVision 8
Controller Display Unit for
ComAp Controllers
SW version 2.6.0
1 Document information 5
2 Applications overview 6
3 Fast navigation 8
4 Operator interface 21
5 Initial Screen 54
6 Features based on USB 56
7 Support of user’s pictures 63
8 Screen modification 66
9 Installation 71
10 InteliVision 8 programming 78
11 Technical data 92

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliVision 8 and is the answer not in the manual?

ComAp InteliVision 8 Specifications

General IconGeneral
Display Size8 inches
Resolution800 x 600 pixels
TouchscreenYes
Operating Temperature-20°C to +70°C
Communication InterfacesEthernet, USB, CAN
Protection RatingIP65

Summary

Document Information

Clarification of Notation

Defines specific symbols and terms used in the document for clear communication.

About This Guide

Provides a general overview of the InteliVision 8 display unit and its capabilities.

Applications Overview

Firmware and PC Software Supporting InteliVision 8

Lists compatible firmware versions and PC software required for InteliVision 8.

Available Related Documentation

Provides links to other relevant documents and feature lists for ComAp controllers.

Fast Navigation

IV8 Front Face

Describes the physical layout and buttons of the InteliVision 8 display.

How to Connect IV8 Display to IGS-NT or ID Controller?

Explains the process of connecting the InteliVision 8 display to ComAp controllers.

How to Enter a Password?

Details the procedure for accessing secured functions using a password.

How to View Important Values?

Guides users on how to access and view critical operational data on the display.

How to View a Controller Status?

Explains how to check the current operational status of the connected controller.

How to View a Breaker Status?

Describes how to monitor the status of circuit breakers associated with the controller.

How to Change a Gen-set Mode?

Provides instructions for switching between different operating modes of the gen-set.

How to Change Setpoints?

Details the process for adjusting configuration parameters (setpoints) for the controller.

How to Find Alarms?

Guides users on locating and identifying active alarms on the system.

Communication Error

Explains how to identify and troubleshoot communication errors with the controller.

How to Change a Password/To Save a Password/To Logout?

Covers user account management including password changes and logout procedures.

How to Change Display Brightness?

Instructions for adjusting the screen brightness for optimal visibility.

Main Icons Description

Explains the meaning of various icons displayed on the InteliVision 8 interface.

Operator Interface

Measurement Screens

Details the various measurement screens displaying real-time operational data.

Trends Screen

Explains how to view and monitor trends of selected values over time.

Setpoints Screens

Covers the interface for setting and modifying system configuration parameters.

AlarmList Screen

Describes how to view and manage system alarms and fault notifications.

History Screen

Details how to access and review historical records of system events and data.

Rules for Help Customization

Information on how to customize or create custom help content for the device.

Change of the Numerical Value

Guides on editing numerical setpoints, including range and input methods.

Text String Selection

Explains how to select text-based values for setpoints from a list.

Text String Edit

Details the process for editing text-based setpoints directly on the interface.

AlarmList for IGS-NT Controllers

Specifics on alarm display and management for IGS-NT controller series.

AlarmList for ID Controller

Specifics on alarm display and management for ID controller series.

History Context Buttons

Describes the buttons used for navigating and interacting with historical data.

Change of an Order of Columns

Instructions on how to reorder columns in the history records for better viewing.

Help/Others Screen

Access point for various settings, controller info, and help resources.

Help Context Buttons

Details the navigation controls within the help and system information sections.

Initial Screen

Additional Information on Initial Screen

Details the information displayed on the initial screen during device startup.

Support of Customized Logo

Explains how to use a custom logo on the initial startup screen.

Features Based on USB

Directory Structure and Names of Files

Defines the expected file organization and naming conventions on USB storage.

Export of History

Guides on saving historical data from the device to a USB drive.

Export/Import of Trends

Details the process for exporting and importing trend data to/from USB.

Export of Archive and InteliVision 8 Firmware

Covers backing up controller archives and firmware to USB storage.

USB as "Login Key"

Explains using a USB stick for quick and secure user login.

Screen Modification

User Definable SoftKeys Buttons

Describes how to assign custom functions to the softkey buttons on the display.

Support of Color Palette

Details the color options available for customizing screen elements.

Transparency Attribute

Explains how to apply transparency to graphical objects on measurement screens.

Support of Tier 4 Final Symbols

Information on using symbols compliant with Tier 4 Final emission standards.

Installation

Terminals and Dimensions

Provides physical dimensions and terminal connection details for the device.

Mounting System

Information on how to physically install the InteliVision 8 unit.

Recommended Wiring

Diagrams and guidelines for correct electrical connections to the controller.

Modules' Address Combination on CAN (IG/IS-NT, ID)

Explains CAN bus address configuration for various modules.

IGS-NT Controllers and 4 InteliVisions 8 on CAN2

Details CAN bus setup for IGS-NT controllers with multiple InteliVisions.

ID-DCU Marine Controller and up to 8 InteliVisions 8 on CAN2

Describes CAN bus configuration for ID-DCU Marine controllers with multiple InteliVisions.

InteliVision 8 Programming

ActiveSync

Covers the use of ActiveSync for connecting and synchronizing with the device.

Windows Mobile Device Center (WMDC)

Explains the use of WMDC for device management and synchronization.

IVProg Running

Details how to start and use the IVProg tool for device programming.

Technical Data

Power Supply

Specifies the electrical power requirements and consumption details.

Operating Conditions

Outlines the environmental and storage conditions for the device.

Climatic, Mechanical and EMC Standards

Lists the compliance standards for environmental and electromagnetic compatibility.

Dimensions and Weight

Provides physical specifications including size and weight of the unit.

Communication Interface

Describes the supported communication protocols and their specifications.

Operating System

Identifies the operating system running on the InteliVision 8 device.

LCD Display

Details the specifications of the device's color TFT LCD screen.