EasyManuals Logo

CompAir DELCOS XL Series User Manual

CompAir DELCOS XL Series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Configuration 5
October 2013 GB 37 /80
Set baudrate
1
Tap button <Baudrate>.
The input menu for setting the baudrate ap-
pears.
2
Tap the <Baudrate> button for the desired
value.
Baudrate entry can be cancelled by tapping the
button <Cancel>. The previously active setting
is used.
3
Tap the <OK> button.
The baudrate is set.
The menu "Communication" appears.
5.5.6 Setting automatic restart after a
power failure
DANGER
In this operating mode, the compressor
may start up automatically at any time.
Provide the compressor with warn-
ing signs.
Keep the compressor room locked.
Instruct personnel.
Install the main switch according to
EN 60204 and attach a warning sign
to it.
5.5.6.1 Automatic re-start
The controller can be set so that the compressor
automatically restarts after a power failure.
The permissible duration of a power failure can be
set. If the duration of the power failures exceeds
the set time, the compressor will not restart auto-
matically. The fault message "E400:Power Sup-
ply Failure" appears in the display. In this case the
compressor must be manually started.
If the compressed air station comprises several
compressors, setting of start delay allows a stag-
gered start-up.
Activating automatic restart
1
Tap the <Settings> tab.
2
Tap the <Control...> button.
3
Press the <arrow keys> until the <Automatic
re-start> button appears.
4
Tap the <Automatic re-start> button.
The input menu "Automatic re-start" opens.
5
Tap the <On> button.
The <Cancel> button can be used to cancel en-
abling of the automatic restart. The previously
active setting is used.
6
Tap the <OK> button.
Automatic restart after a power failure is en-
abled.
The "Control" menu appears.
On the <Automatic re-start> button the text
changes to "On".
In the menu "Home" it is also indicated that
automatic restart is enabled.
Tapping the button <Off> in the menu "Automatic
re-start" causes automatic restart to be disabled
again.
Setting the maximum power loss time
1
Tap the <Settings> tab.
2
Tap the <Control...> button.
3
Press the <arrow keys> until the <- Max. Power
Loss Time> button appears.
4
Tap the <- Max. Power Loss Time> button.
The input menu "- Max. Power Loss Time"
opens.
5 Tap the <arrow keys> to set the desired maxi-
mum power loss time.
The <Cancel> button can be used to cancel
setting of the maximum power loss time. The
previously active setting is used.
6
Tap the <OK> button.
The maximum power loss time is set.
The "Control" menu appears.
The set power loss time is now displayed on
the button <- Max. Power Loss Time>.
NOTE
The power loss time can be set to "unlimited".
This is not permissible in some countries. Con-
tact Gardner Denver for advice.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CompAir DELCOS XL Series and is the answer not in the manual?

CompAir DELCOS XL Series Specifications

General IconGeneral
BrandCompAir
ModelDELCOS XL Series
CategoryController
LanguageEnglish

Related product manuals