Discharge Conveyor
A discharge conveyor offers support before, during, and after
cutting, and facilitates the removal of cut parts. Discharge
conveyors are available in the following sizes:
● 6 inches wide by 6 feet long
● 6 inches wide by 12 feet long
● 6 inches wide by 16 feet long
Isolation Transformer
The isolation transformer protects sensitive electronics from
incoming power, which helps prevent errors caused by electri-
cal noise. It also protects equipment from electrical noise gen-
erated by the servo motor and associated amplifier.
NOTE: An isolation transformer will not compensate for a
ground that does not meet code requirements.
Left to Right Machine Operation
This option changes the machine direction from the standard
right to left extrusion flow.
Your Conair sales representative can analyze your needs and
recommend the options that are right for your system.
NOTE: Conair strongly recommends using an
isolation transformer. Ensuring clean and proper
power can help avoid the need for costly service
calls.