4-36 OPERATION
UGE048/1103 CSC Combination Puller/Cutter
MAKING
ADJUSTMENTS
DURING
OPERATION
FOR THE CUTTER
There are several adjustments you can make during normal
cutting. These adjustments include:
● In Timer mode, adjust the time between cuts
● In Encoder and Follower modes, adjust the length
● In Product mode, adjust the hold-off time
● In Flywheel mode, adjust blade speed (CSC only)
● Adjust blade speed in all modes except
Follower
● Perform a manual cut and reset the length by press-
ing the manual cut button at any time during on-demand
cutting. Pressing Reset/Test has no effect during contin-
uous cutting.
● Count the total number of cuts by pressing the Total
On/Off soft key. Use the Reset button to return the count
to zero. This feature is useful for collecting samples dur-
ing a production run.
● Count the batches of cuts by pressing the Total On/Off
soft key. Use the Reset button to return the count to
zero. This feature is useful for collecting samples during
a production run.
● Stop cutting temporarily by setting Cut On/Off to off.
This allows you to view the cutting blade (through the
window) or perform other tasks without shutting down
the cutter.
NOTE: While the controller will allow you to
switch modes during operation, this is not
recommended.