CSC Combination Puller/Cutter UGE048/1103
1-4 INTRODUCTION
WARNING: Voltage Hazard
This equipment is powered by one- or three-
phase alternating current, as specified on the
machine serial tag and data plate.
A properly-sized conductive ground wire from
the incoming power supply must be connected
to the chassis ground terminal inside the electri-
cal enclosure. Improper grounding can result in
severe personal injury and erratic machine
operation.
Always disconnect and lockout power before
opening the electrical enclosure or performing
non-routine procedures such as maintenance.
ATTENTION:
R
EAD THIS SO NO
ONE GETS HURT
DANGER: Pinch Hazard!
Never remove or disable safety devices to sus-
tain production. Operating without these
devices could lead to hazardous conditions that
can cause severe injury.
● Walk-through style belt guards which protect
from injury, but also allow side entry for ease
of operation. Upper and lower belt guards
independently protect the operator from
being caught in the belts or associated dri-
ven sheaves.
● The power cord is attached to the upper
guard by a receptacle on the rear side of the
guard. You must disconnect this power cord
to remove the upper belt guard, ensuring
that the puller will not start if the upper guard
is not in place.
● The flip up safety switch on the discharge
end of the upper belt guard allows operation
only when in the down position. If a finger or
piece of clothing is caught on the upper belt
and drawn in, the guard flips up and immedi-
ately shuts off the power to the entire combi-
nation puller/cutter.