EasyManua.ls Logo

Conair CSC - Puller Operation Control

Conair CSC
141 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Apply power to the machine.
Place the disconnect in the “ON” position.
Check to insure to 10-turn speed potentiometer
is turned to zero speed. (Counter-clockwise fully).
Note: Whenever the puller is turned off,
the speed potentiometer should be rotated
to zero speed. In this way, when the unit is
started, it will be in a safe operational mode.
Open the gap between the puller belts to the desired
gap for the product to be pulled.
Depress the green “START” button to start the
drive.
Note: If the puller does not start, make sure
the “E-Stop” button is pulled out in the
extended position.
Using the 10-turn potentiometer, adjust the puller
speed.
Note: Turn in a clockwise direction to
increase speed and counter-clockwise to
decrease speed.
A digital line rate indicator (optional) can be used
to set the desired puller speed.
Note: This display should be programmed
in feet per minute, with one decimal point
(tenths of feet per minute), unless otherwise
specified.
1
3
4
2
5
6
PULLER
OPERATION
CONTROL
OPERATION 4-27
UGE048/1103 CSC Combination Puller/Cutter
NOTE: For optional Servo
Control see Appendix F.