38 • Crestron Pyng OS 2 for CP4-R Product Manual – DOC. 8432A
4. Choose the appropriate relay behavior from the Operation Mode menu:
• If a Momentary behavior is selected, the controlled device is set (turned on) or
reset (turned off) by a relay command, and remains in the selected state for a
set duration.
• If a Latching behavior is selected, the controlled device is set or reset by a relay
command, and remains in the selected state until an inverse command is sent.
5. Select a relay connection from the Relay / Digital Input Configuration menu.
6. Tap the gear button next to a relay or input to set a hardware connection for
the selected behavior.
Fireplace1: Off Hardware Connection
NOTE: The appropriate devices must be added to the system prior to configuring
a hardware connection.
a. Select the appropriate input port from the provided options.
b. If applicable, select the sensor monitoring state (On or Off).
c. If applicable, select the sensor contact states when turning off the relay
device (
Contacts Are Open or Contacts Are Closed).
d. Tap the checkbox next to Enable Pull-Up Resistor to enable or disable using a
pull-up resistor for the hardware connection. A checked box indicates an
enabled pull-up resistor.
7. Tap the Test tab to view and test the configured relay behavior(s). The hardware
connection for the relay behavior(s) must be configured before they may be
tested.