CVC TECHNOLOGIES, INC. CVC 400 OPERATION MANUAL
7 - 8
Note:
All the LED indicators should be ON when power is ON (D11 red LED is flashing or ON).
The standard operation procedures of MV are as below:
a. Speed adjustment:
Conveyor speed: Press product speed twice, set the value at 255 (max) and then press ENTER key.
Label roller speed: Press product speed three times, and adjust the speed at 255.
Separator motor speed: Press key twice, and adjust the speed at 255.
b. Set the voltmeter at “DCV” mode.
MV (Max Voltage): Connect positive probe (+) to M+, and negative probe (–) to M-. Adjust MV, and then check the
voltage value with a voltmeter.
*CL (Current Limit): No adjustment is required.
*OL (Over current Limit): No adjustment is required.
Maximum motor voltage:
Label roller motor: 90V
Separator motor: 90V
*Conveyor motor: 130V
c. Check the following if the conveyor, wrap belt and separator motor do not work when the machine is turned on:
1) Check if the fuse F1 is burned out. If not, use voltmeter to check input/output voltage.
2) Set voltmeter at "DCV" mode.
3) Connect the positive probe (+) to VIN (BRN) and the negative probe (–) to GND (ORG). And then check if the input
voltage is normal. If so, continue to check the output voltage by testing M+ and M-.
4) Replace a new DC motor driver if output voltage is abnormal.