EasyManuals Logo
Home>Danfoss>DC Drives>vlt FC 102

Danfoss vlt FC 102 Programming Guide

Danfoss vlt FC 102
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
Parameter 1-10 Motor
Construction
[0]
Asynchron
[1] PM Motor
non salient
Parameter 1-14 Damping Gain x
Parameter 1-15 Low Speed Filter
Time Const.
x
Parameter 1-16 High Speed Filter
Time Const.
x
Parameter 1-17 Voltage lter time
const.
x
Parameter 1-20 Motor Power [kW] x
Parameter 1-21 Motor Power [HP] x
Parameter 1-22 Motor Voltage x
Parameter 1-23 Motor Frequency x
Parameter 1-24 Motor Current x x
Parameter 1-25 Motor Nominal
Speed
x x
Parameter 1-26 Motor Cont. Rated
Torque
x
Parameter 1-28 Motor Rotation
Check
x x
Parameter 1-29 Automatic Motor
Adaptation (AMA)
x
Parameter 1-30 Stator Resistance
(Rs)
x x
Parameter 1-31 Rotor Resistance (Rr) x
Parameter 1-35 Main Reactance (Xh) x
Parameter 1-37 d-axis Inductance
(Ld)
x
Parameter 1-39 Motor Poles x x
Parameter 1-40 Back EMF at 1000
RPM
x
Parameter 1-50 Motor Magneti-
sation at Zero Speed
x
Parameter 1-51 Min Speed Normal
Magnetising [RPM]
x
Parameter 1-52 Min Speed Normal
Magnetising [Hz]
x
Parameter 1-58 Flying Start Test
Pulses Current
x x
Parameter 1-59 Flying Start Test
Pulses Frequency
x x
Parameter 1-60 Low Speed Load
Compensation
x
Parameter 1-61 High Speed Load
Compensation
x
Parameter 1-62 Slip Compensation x
Parameter 1-63 Slip Compensation
Time Constant
x
Parameter 1-64 Resonance
Dampening
x
Parameter 1-65 Resonance
Dampening Time Constant
x
Parameter 1-66 Min. Current at Low
Speed
x
Parameter 1-70 Start Mode x
Parameter 1-10 Motor
Construction
[0]
Asynchron
[1] PM Motor
non salient
Parameter 1-71 Start Delay x x
Parameter 1-72 Start Function x x
Parameter 1-73 Flying Start x x
Parameter 1-77 Compressor Start
Max Speed [RPM]
x
Parameter 1-78 Compressor Start
Max Speed [Hz]
x
Parameter 1-79 Compressor Start
Max Time to Trip
x
Parameter 1-80 Function at Stop x x
Parameter 1-81 Min Speed for
Function at Stop [RPM]
x x
Parameter 1-82 Min Speed for
Function at Stop [Hz]
x x
Parameter 1-86 Trip Speed Low
[RPM]
x x
Parameter 1-87 Trip Speed Low [Hz] x x
Parameter 1-90 Motor Thermal
Protection
x x
Parameter 1-91 Motor External Fan x x
Parameter 1-93 Thermistor Source x x
Parameter 2-00 DC Hold/Preheat
Current
x
Parameter 2-01 DC Brake Current x x
Parameter 2-02 DC Braking Time x
Parameter 2-03 DC Brake Cut In
Speed [RPM]
x
Parameter 2-04 DC Brake Cut In
Speed [Hz]
x
Parameter 2-06 Parking Current x
Parameter 2-07 Parking Time x
Parameter 2-10 Brake Function x x
Parameter 2-11 Brake Resistor (ohm) x x
Parameter 2-12 Brake Power Limit
(kW)
x x
Parameter 2-13 Brake Power
Monitoring
x x
Parameter 2-15 Brake Check x x
Parameter 2-16 AC brake Max.
Current
x
Parameter 2-17 Over-voltage Control x
Parameter 4-10 Motor Speed
Direction
x x
Parameter 4-11 Motor Speed Low
Limit [RPM]
x x
Parameter 4-12 Motor Speed Low
Limit [Hz]
x x
Parameter 4-13 Motor Speed High
Limit [RPM]
x x
Parameter 4-14 Motor Speed High
Limit [Hz]
x x
Parameter 4-16 Torque Limit Motor
Mode
x x
Parameter Descriptions
VLT
®
HVAC Drive FC 102
50 Danfoss A/S © 10/2019 All rights reserved. M0010001
33

Table of Contents

Other manuals for Danfoss vlt FC 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt FC 102 and is the answer not in the manual?

Danfoss vlt FC 102 Specifications

General IconGeneral
BrandDanfoss
Modelvlt FC 102
CategoryDC Drives
LanguageEnglish

Related product manuals