8.3 Acoustic Noise or Vibration
If the motor or the equipment driven by the motor, e.g., a fan blade, is making noise or vibrations at certain frequencies, try
the following:
Speed Bypass, parameter group 4-6* Speed Bypass
Overmodulation, 14-03 Overmodulation set to [0] Off
Switching pattern and switching frequency parameter group 14-0* Inverter Switching
Resonance Dampening, 1-64 Resonance Dampening
The acoustic noise from the adjustable frequency drive comes from three sources:
1. DC intermediate circuit coils
2. Integral fan
3. RFI filter choke
Frame Level [dBA]
H1 57.3
H2 59.5
H3 53.8
H4 64
H5 63.7
H6 71.5
H7 67.5 (75 kW 71.5 dB)
H8 73.5
H9 60
H10 62.9
I2 50.2
I3 54
I4 60.8
I6 70
I7 62
I8 65.6
Table 8.9 Typical Values Measured at a Distance of 3.3 ft [1 m] from the Unit
General Specifications and ... Design Guide
MG18C522 Danfoss A/S © Rev. 2014-01-14 All rights reserved. 117
8 8

Table of Contents

Other manuals for Danfoss VLT HVAC Basic Drive FC 101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT HVAC Basic Drive FC 101 and is the answer not in the manual?

Danfoss VLT HVAC Basic Drive FC 101 Specifications

General IconGeneral
BrandDanfoss
ModelVLT HVAC Basic Drive FC 101
CategoryDC Drives
LanguageEnglish

Related product manuals