CR805 Retransfer Card Printer Installation and Administrator’s Guide 83
Change settings as needed, and then click Set Current to apply changes.
CardStockDisplayed—Select the card stock whose settings you want to view and change on
this page. Click Set Current to apply the card stock. You must do this before making any
changes to the card stock settings. The changes you make to the settings on this page apply
to the selected card stock. Click Set Current again to save your changes.
The settings apply whenever the named card stock is loaded in the printer, as specified in
Hopper1CardStockLoaded or ExceptionCardStock Loaded.
You can define up to 10 card stock types.
DebowDelay—The time, in milliseconds, to delay after debowing the card. You can set a
different value for each card stock specified in CardStockDisplayed.
DebowDistance—The distance necessary to debow the specified card type. You can set a
different value for each card stock specified in CardStockDisplayed.
DebowDwell—The time, in milliseconds, to apply the debow action to the specified card
stock. You can set a different value for each card stock specified in CardStockDisplayed.
DirectPeelLaminationSpeed—The speed at which to apply the retransfer film to side 2 of the
card if the card design includes inhibitor or smart card programming. The setting applies to
the card stock specified in CardStockDisplayed.
ExceptionCardStockLoaded—The card stock that will be inserted in the exception slot.
ExceptionCardStockLoaded CardStock1
Hopper1CardStockLoaded CardStock1
RetransferCoolTime 0 0 [0 – 10000]
RetransferLaminationSpeed 12.0 12 [10.0 – 34.0]
RetransferLaminationSpeed
Layer2
15.0 15 [10.0 – 34.0]
RetransferLaminationSpeed
Layer2Side2
15.0 15 [10.0 – 34.0]
RetransferLaminationSpeed
Side2
12.0 12 [10.0 – 34.0]
RetransferRollerTemp 165 165 [140 – 190]
RetransferRollerTempSide2 165 165 [140 – 190]
Description Default Value
Current Value
(unit) Allowed Range