DM16E1 / DM4E1 Operation and Installation Manual - 204-4001-19 58
# -------------------------------------------------------------------------
# DataCom Telematica - DM16E1 Multiplexer
# /local/test/ports/Agg
# -------------------------------------------------------------------------
# Test functions
# Slot AG1 - Port 01 - E3 SM Short Range Bidirectional 1310nm
#
#
# Test Function :[ None ]
#
#
#
#
#
# 1 - None
# 2 - Start LDL
# 3 - Start LAL
#
# Option: [ ]
# -------------------------------------------------------------------------
# <ESC> Return to Previous Menu
# [N]ext Card <PgDn>
# -------------------------------------------------------------------------
None: Normal operation on the interface.
Running LDL / LAL: Indicates test activation.
The options 1)None, 2)Start LDL, and 3)Start LAL activate/deactivate tests on the interface.
The activation of tests on remote aggregate interfaces causes loss of the management link and
should not
be set. If this setting is made by accident will be necessary to deconfigure the test locally.