DM16E1 / DM4E1 Operation and Installation Manual - 204-4001-19 85
# -------------------------------------------------------------------------
# DataCom Telematica - DM16E1 Multiplexer
# /local/Net/router/FRspecial
# -------------------------------------------------------------------------
# Frame Relay Status Parameters Configuration
#
#
# T391 (Polling timer) : [10]
# N391 (Polling counter) : [006]
# N392 (Error threshold) : [03]
# N393 (Events counter) : [04]
#
#
#
#
#
#
#
#
#
# -------------------------------------------------------------------------
# <ENTER> Return and Save <ESC> Return without Saving
# -------------------------------------------------------------------------
• T391 (Polling timer): Time (in seconds) elapsed between packets of network verification.
• N391 (Polling counter): Number of packets of network verification between two status packets.
• N392 (Error threshold): Number of errors allowed at every N393 events.
• N393 (Event counter): Size of the event window.