MATRIX 300™ REFERENCE MANUAL
6
1
Learn
6. Enter the Learn function by pressing and holding
the X-PRESS™ push button until the Learn LED is
on.
7. Release the button to enter the Learn function.
The Learn LED will blink until the procedure is
completed.
The Learn procedure ends when the Image
Processing and Decoding parameters are
successfully saved in the reader memory, the
Green Spot is activated, the Learn LED will stop
blinking and Matrix 300™ emits 3 high pitched
beeps
1
.
If the autolearning cannot be reached after a
timeout of about 3 (three) minutes Matrix 300™ will
exit without saving the parameters to memory, the
Learn LED will stop blinking and in this case Matrix
300™ emits a long low pitched beep.
Figure 7 X-PRESS™ Interface: Learn
Function
NOTE: The Grade A Barcode Test Chart cannot be used to set the Code
128 symbology (even though the reader successfully reads the code). Use
the application specific code if you need to set this symbology.
NOTE: You can exit the Learn function at any time by pressing the X-
PRESS™ push button once. After a short delay the Learn procedure is
cancelled.
NOTE: If you have used this procedure to configure Matrix 300™ go to step
7.
Reset Reader to Factory Default (Optional)
If it ever becomes necessary to reset the reader to the factory default values, you can
perform this procedure by holding the X-PRESS™ push button pressed while powering up
the reader. You must keep the X-PRESS™ push button pressed until the power up
sequence is completed (several seconds) and all LEDs blink simultaneously 3 times.
All LEDs remain on for about 1 second, then off for one second, the Configuration and
Environmental parameters are reset, and the status LED remains on. If connected through a
CBX500 with display module, the message "Default Set" is shown on the display.
1
The Learn procedure will not recognize Pharmacode symbologies.

Table of Contents

Other manuals for Datalogic Matrix 300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Matrix 300 and is the answer not in the manual?

Datalogic Matrix 300 Specifications

General IconGeneral
BrandDatalogic
ModelMatrix 300
CategoryBarcode Reader
LanguageEnglish

Related product manuals