MATRIX 300™ REFERENCE MANUAL
26
2
6. If necessary, set the ID-NET™ baudrate from the Reading System Layout >
Device Network Setting > Network Baud Rate parameter, (500 kbs default).
7. Configure the other device parameters via VisiSet™ [Operating Mode, Calibration, Data
Collection parameters, etc.].
8. The Slave device is now Configured. Physically connect it to the Master/Slave network. If
using the CBX connection box equipped with a BM100 Backup module, you can perform
Device Backup at the Slave (see par. 2.4 for details).
The Slave device is now Configured. Repeat these steps for each Slave reader in the ID-
NET™ network.
Configuration of Master
1. Connect a PC equipped with VisiSet™ to the Main, Auxiliary or Ethernet interface of the
planned Master reader.
2. Launch VisiSet™ and connect to the Master reader.
3. From the VisiSet™ Device Menu select "Parameter Setup".
4. Set the Role of the Master reader (Synchronized or Multidata) from the
Reading System Layout > Device Network Setting > Topology Role parameter.
5. Enable the planned Slave device N from the Reading System Layout >
Expected Slave Device #N > Status parameter and, if desired, set the related
identification string from the Expected Slave Device #N > Device Description parameter.
Repeat this step for all planned Slave devices.
6. If necessary, set the ID-NET™ baudrate from the Reading System Layout >
Device Network Setting > Network Baud Rate parameter, (500 kbs default).
7. Configure the other device parameters via VisiSet™ [Operating Mode, Calibration, Data
Collection parameters, etc.].
8. The Master device is now Configured. Physically connect it to the Master/Slave network.
If using the CBX connection box equipped with a BM100 Backup module, perform a
Network Backup at the Master (see par. 2.4 for details).
9. From the VisiSet™ Device Menu select "ID-NET™ Status Window" and click on the
"Look For Devices On Network" button to check the status of the expected Slave devices
within the ID-NET™ network.

Table of Contents

Other manuals for Datalogic Matrix 300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Matrix 300 and is the answer not in the manual?

Datalogic Matrix 300 Specifications

General IconGeneral
BrandDatalogic
ModelMatrix 300
CategoryBarcode Reader
LanguageEnglish

Related product manuals