1D Symbologies Enter/Exit Programming Mode
Product Reference Guide  
                   141
Industrial 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control on page 
140. Length 1 is the minimum label length if in Variable Length on page 113 Mode, or the first 
fixed length if in Fixed Length on page 113 Mode. Length includes the bar code’s data charac-
ters only. The length can be set from 0 to 50 characters.
Table 11 provides some examples for setting Length 1. See page 243 if you want detailed 
instructions on setting this feature.
Table 11. Industrial 2 of 5 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 1 SETTING
4
Scan Two Characters From 
Appendix D, Keypad
 ‘0’ and ‘0’  ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Industrial 2 of 5 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save 
the entry string. You can then start again at the beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character