Scanning Features
Product Reference Guide  
                   257
Aiming Duration Time
Specifies the frame of time the aiming pointer remains on after decoding a label, when in trig-
ger single mode. The range for this setting is from 1 to 255
 seconds in 1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three di
gits. For example: 0 = 000, 5 = 005, 20 
= 020, etc.
3. Go to page 82 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT AIMI
NG DURATION TIME SETTING.
5. Scan the appropriate three digits from the keypad in Appendix D, Keypad, that represent 
the duration which was determined in the steps above. You will hear a two-beep indication 
afte
r the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and 
not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 40 for some examples of how to set this feature.
Table 40. Aiming Duration Time Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.)
255 Seconds (4.25 
min
.)
2 Pad leading zero(es)
001 090 180 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT AIMING DURATION TIME SETTING
5
Scan Three Characters From 
Appendix D, Keypad
‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE