Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable 
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired settin
g by 100 (setting is in 100ms increments). Pad the result with 
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Go to page 81 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT FLAS
H OFF TIME SETTING.
5. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the 
duration which was determined in the steps above. You will hear a two-beep indication 
afte
r the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and 
not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 42 for some examples of how to set this feature.
Table 42. Flash Off Time Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.)
2
Divide by 100 (and pad with 
lead
ing zeroes to yield two 
digits)
05 10 52 99
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT FLASH OFF TIME SETTING
5
Scan Two Characters From 
Appendix D, Keypad
 ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’  ‘9’ and ‘9’