Description of fields within Sub-Register 0x36:28 – PMSC_LEDC
BLINK_TIM
reg:36:28
bits:7–0
Blink time count value. This field determines how long the LEDs remain lit after an event that
causes them to be set on. This time is specified in units of 14 ms so the default value of 0x20
will give an on blink of 400 ms followed by an off blink of 400 ms. The BLNKEN bit (below)
must be set to enable this blink functionality.
Blink Enable. When this bit is set to 1 the LED blink feature is enabled.
Because the LED blink counter uses the low frequency KHZCLK timer, this timer must be
enabled as per Sub-Register 0x36:00 – PMSC_CTRL0 and configured as per Sub-Register
0x36:04 – PMSC_CTRL1
BLNKNOW
reg:36:28
bits:19:16
Manually triggers an LED blink. There is one trigger bit per LED IO.
7.2.51 Register files: 0x37 to 0x3F – Reserved
Reserved – these register files are reserved
Register map register files 0x36 through 0x3F are reserved for future use. Please take care not to write to