GC-1F Installation Instructions and Reference Handbook
DEIF A/S Page 89 of 123
Parameter overview
Parameter group 1 (Disp. view settings)
6123 Service timer 2: Days
6181 Start prepare 6126 Service timer 2: Reset
6183 Start On time 6130 Alarm horn
6184 Start Off time 6221 Hz/V OK timer
6211 Cool-down 6222 Hz/V OK voltage
6212 Extended stop 6223 Hz/V OK frequency
Parameter group 2 (Disp. view settings)
6901 Alarm jump
1030 Over-current 1: Delay + Set point 7041 AMF test time (B3)
1040 Over-current 2: Delay + Set point 7062 Mains OK U (B3)
1130 Gen short circuit 1 Delay + Set point 7065 Mains failure U low (B3)
1140 Gen short circuit 2 Delay + Set point 7066 Mains failure U high (B3)
1150 Over-voltage 1: Delay + Set point 7072 Mains OK f (B3)
1160 Over-voltage 2: Delay + Set point 7075 Mains failure f low (B3)
1170 Under-voltage 1: Delay + Set point 7076 Mains failure f high (B3)
1180 Under-voltage 2: Delay + Set point 7091 Island test time
1210 Over-frequency 1: Delay + Set point 7513 Service mode (RTU/ASCII)
1220 Over-frequency 2: Delay + Set point
7560 Engine I/F
1240 Under-frequency 1: Delay + Set point 7565 EIC Auto view (H5)
1250 Under-frequency 2: Delay + Set point 9151 Backlight dimmer
1450 Overload 1: Delay + Set point Hour adjust. ( “Sync. clock” to PC button)
1460 Overload 2: Delay + Set point Minutes adjust. ( “Sync. Clock” to PC button)
Parameter group 3 (Disp. view settings)
Seconds Adjust.( “Sync. Clock” to PC button)
4220 Fuel 1.1: Delay + Set point* Date adjust ( “Sync. Clock” to PC button)
4230 Fuel 1.2: Delay + Set point* Month adjust ( “Sync. Clock” to PC button)
4620 Fuel 1.3: Delay + Set point* Year adjust ( “Sync. Clock" to PC button)
4600 V-belt: Delay
Parameters only configurable from USW
4610 Charger gen: Delay 1000 Reverse power
6350 D+: Delay 1620 Mains voltage unbalance
6550 Fuel pump: Delay* 2150 Phase sequence error
6551 Fuel pump 1: Set point* 2200-2210 MB control
6552 Fuel pump 2: Set point* 2280 Phase rotation
* Only shown if multi-input 1 is set to VDO
2160-2170 GB control
Always shown parameters in display
2770 EIC control
1985 Ext. run fb. fail
3000-3050 Digital input term. 10-15
4560 Hz/V failure timer 3490 Emergency stop
4580 Stop fail
3400…3420 Binary multi-input settings
4960 Battery low 1: Delay + Set point
4120…4390 mA input settings
4970 Battery High: Delay + Set point
4310…4470 VDO multi-input settings
6070 Genset mode (B3) 4510 Gen. overspeed 1
6101 Running time 4520 Gen. overspeed 2
6103 Number of GB operations 4580 Stop fail
6104 Number of MB operations (B3) 4630 Low water temp.
6105 kWh reset 4950 Battery low 2
6112 Service timer 1: Hours 5000...5060 Relay functions
6113 Service timer 1: Days 6001…6005 Nominal settings 1
6116 Service timer 1: Reset 6006 Enable nom. Settings
6122 Service timer 2: Hours 6011…6015 Nominal settings 2

Table of Contents

Other manuals for Deif GC-1F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Deif GC-1F and is the answer not in the manual?

Deif GC-1F Specifications

General IconGeneral
BrandDeif
ModelGC-1F
CategoryController
LanguageEnglish

Related product manuals