Table 8. 1600 W AC/1600 W HVDC PSU indicators
Component Indicator Condition
AC power indicator Solid amber
Standby mode with Fan Lock for
15 seconds.
Standby mode with OTP range
Active mode with +12 V DC Fault
Active mode with Fan Lock for 15
seconds.
Solid green DC_OK (power good)
Blinking green Standby mode normal
Off Unit without AC power
Baseboard Management Controller (BMC) heart beat LED
The system board provides BMC heart beat LED (CR17) for BMC debugs. The BMC heart beat LED is
green. When the system AC power is connected, the LED glows. When BMC firmware is ready, the BMC
heart beat LED blinks.
Figure 11. BMC heart beat LED on the C6320 system board
1. BMC heart beat LED
System configuration limitations by Intel Xeon processor
E5-2600 v3 and E5-2600 v4 product family
NOTE: Certain system hardware configurations may require reductions in the upper temperature
limits.
NOTE: System performance may be impacted when operating above 30°C or with a fan fault.