Cable routing for SATADOM and LSI 2008
Figure 35. Cable Routing for SATADOM and LSI 2008
Table 26. Cable Routing for SATADOM and LSI 2008
Item Cable From (LSI 2008 SAS Mezzanine
Card)
To (System Board)
Mini-SAS cable
Mini-SAS connector 4-7 (J4)
On LSI 2008 SAS Mezzanine Card
SAS/SATA connectors 4&5
Mini-SAS connector 0-3 (J3)
On LSI 2008 SAS Mezzanine Card
Mini-SAS HD Connector 0-3
SATADOM
power cable
SATADOM
HDD Power Connector on the
system board
Power supply units
NOTE: Configurations higher than indicated in the table may change the PSU mode to non-
redundant. In non-redundant mode if the power requirement exceeds the installed system power
capacity, the BIOS will throttle the processors. Also, since Processor Power Capping is enabled,
processor throttling occurs on configurations that exceed the cap value.
NOTE: Both the PSUs are hot swappable, and they can support hot swap in any condition if the
system has power throttling feature.
The following table lists the maximum supported configuration where power supply unit (PSU)
redundancy is guaranteed:
Table 27. PSUs configuration
PSU Four system boards
1400 W Up to two 120 W processor per system board, three hard drives per system board,
and four memory modules per system board
1600 W Up to two 120 W processor per system board, three hard drivesper system board, and
eight memory modulesper system board