Table 19. Maximum shock specifications
Maximum shock Specifications
Operating One shock pulse in the positive z axis (one pulse
on each side of the system) of 31 G for 2.6 ms in
the operational orientation.
Storage
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 27 G faired square wave
pulse with velocity change at 235 inches per
second (597 centimeters per second)
Table 20. Maximum altitude specifications
Maximum altitude Specifications
Operating -15.2 m to 3,048 m (-50 to 10,000 ft.)
Storage -15.2 m to 10,668 m (-50 to 35,000 ft.)
Table 21. Airborne contaminant level specification
Airborne contaminant level (Class) G1 as defined by ISA-S71.04-1985
32