3. Follow the procedure listed in Before working on your system.
Steps
Slide the PSU into the PSU bay until the PSU is fully seated and the orange release latch snaps into place.
Figure 74. Installing a power supply unit
Next steps
1. If you have unlatched or removed the cable management accessory, reinstall or relatch it. For information about the cable
management when the PSU is removed or installed while the system is in the rack, see the system's cable management
accessory documentation at PowerEdge manuals.
2. Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION:
When connecting the power cable to the PSU, secure the cable to the PSU with the strap provided
on the handle.
NOTE: When installing, hot swapping, or hot adding a new PSU, wait for 15 seconds for the system to recognize the
PSU and determine its status. The PSU redundancy may not occur until discovery is complete. Wait until the new PSU is
discovered and enabled before you remove the other PSU. The PSU status indicator turns green to signify that the PSU
is functioning properly.
3. Follow the procedure listed in After working inside your system.
Power interposer board (PIB)
Removing the PIB
Prerequisites
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedure listed in Before working on your system.
3. Remove air shroud.
4. Remove the power supply unit.
Installing and removing system components
101