Table 16. Supported video resolution options (continued)
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 85 Hz 32
1280 x 800 60 Hz 32
1280 x 800 75 Hz 32
1280 x 1024 60 Hz 32
1280 x 1024 75 Hz 32
1360 x 768 60 Hz 32
1440 x 900 60 Hz 32
1440 x 900 60 Hz (RB) 32
1600 x 900 60 Hz (RB) 32
1600 x 900 60 Hz (RB) 32
1600 x 1200 60 Hz 32
1600 x 1200 60 Hz (RB) 32
1680 x 1050 60 Hz (RB) 32
1680 x 1050 60 Hz 32
1920 x 1080 60 Hz 32
1920 x 1080 60 Hz (RB) 32
1920 x 1200 60 Hz 32
1920 x 1200 60 Hz (RB) 32
Environmental specifications
NOTE:
For additional information about environmental certifications, refer to the Product Environmental Datasheet located
with the Documentation on www.dell.com/support/home.
Table 17. Continuous Operation Specifications for ASHRAE A2
- Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
1035°C (5095°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (33.8°F/984 Ft) above
900 m (2953 Ft)
Table 18. Continuous Operation Specifications for ASHRAE A3
- Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
540°C (41104°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (33.8°F/574 Ft) above
900 m (2953 Ft)