EasyManua.ls Logo

Dell PowerEdge R360 - Drives; Removing a Drive Blank

Dell PowerEdge R360
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 32. Configuration 4: - 8 x 2.5 inch SAS/SATA and internal PERC card
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 60. Connector descriptions for 8 x 2.5 inch SAS/SATA and internal PERC card
Order From To
1 CTRL_SRC_SA1 (adapter PERC
controller connector)
BP_DST_SA1 (backplane signal
connector)
2 PIB (system board connector) PIB_SIG_1 (PIB signal connector)
3 P1 (system board power connector) SYS (PIB power connector)
4 P2 (system board power connector) CPU (PIB power connector)
5 SIG_PWR_1(PIB power connector) BP_PWR_1 (backplane power
connector)
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Drives
Removing a drive blank
Prerequisites
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedure listed in Before working on your system.
CAUTION: To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
CAUTION: Mixing drive blanks from previous generations of PowerEdge servers is not supported.
66 Installing and removing system components