Figure 32. Configuration 4: - 8 x 2.5 inch SAS/SATA and internal PERC card
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 60. Connector descriptions for 8 x 2.5 inch SAS/SATA and internal PERC card
Order From To
1 CTRL_SRC_SA1 (adapter PERC
controller connector)
BP_DST_SA1 (backplane signal
connector)
2 PIB (system board connector) PIB_SIG_1 (PIB signal connector)
3 P1 (system board power connector) SYS (PIB power connector)
4 P2 (system board power connector) CPU (PIB power connector)
5 SIG_PWR_1(PIB power connector) BP_PWR_1 (backplane power
connector)
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Drives
Removing a drive blank
Prerequisites
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedure listed in Before working on your system.
CAUTION: To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
CAUTION: Mixing drive blanks from previous generations of PowerEdge servers is not supported.
66 Installing and removing system components