NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 69. 4 x 3.5-inch SAS3/SATA RAID
Order From To
1 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
2 SL1 (signal connector on system board) CTRL_DST_PA1 (front PERC)
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Figure 68. Configuration 1-3: 4 x 3.5-inch SAS3/SATA RAID with Rear 2 x E3.S G5x4
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 70. 4 x 3.5-inch SAS3/SATA RAID with Rear 2 x E3.S G5x4
Order From To
1 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
2 SL1 (signal connector on system board) CTRL_DST_PA1 (front PERC)
3 SIG_PWR_1 (system board power connector) R_BP_PWR_1 (rear backplane power connector)
4 SL9 (signal connector on system board) R_BP_DST_PA1(rear backplane signal connector)
Installing and removing system components 97