OPERATOR'S MANUAL
TROUBLESHOOTING/ 65
Dj SEED MANAGER® SE PLANTER MONITOR
BENCHMARK Series® 11001-1218-200112 Rev A
ERROR CODE E31 X
Too Many Seed Sensors are connected to Module X (X is the number of the module,
and Modules are numbered from the far Left side of the implement to the far Right
side of the implement).
Probable Cause
1. Number of Seed Sensors for Module X Configuration is Incorrect.
2. Implement Harness is connecting the Wrong Seed Sensors to Module X.
Corrective Action
1. Check the Number of Seed Sensors for Module X Configuration in SETUP
MODE with the actual number of Seed Sensors connected.
2. Check harness connection to sensor number that corresponds with the number
in the lower display.
ERROR CODE E40
Too Few Hopper Sensors are connected to the system
Probable Cause
1. Number of Hopper Sensors Configuration is incorrect.
2. Hopper Sensors are Failed
3. Implement Harness is not Connected to all Hopper Sensors
4. Harnessing cut and/or pinched
Corrective Action
1. Check the Number of Hopper Sensors Configuration in SETUP MODE with
the actual number of Hopper Sensors connected.
2. Contact DICKEY-john Technical Support for a replacement sensor. See inside,
back cover of this manual for phone number.
3. Check harness connection to sensor number that corresponds with the number
in the lower display.
4. Locate the fault and repair wires by splicing, soldering, and sealing wires.