ERROR CODE E70
Module Supply Voltage is too Low (Shorted to 5v or to Ground)
Probable Cause
1. Harnessing cut and/or pinched
2. Module is defective
Corrective Action
1. Locate the fault and repair wires by splicing, soldering, and sealing wires.
2. Contact DICKEY-john Technical Support for a replacement module. See inside,
back cover of this manual for phone number.
ERROR CODE E71
Module Supply Voltage is too High (Shorted to 12v)
Probable Cause
1. Harnessing cut and/or pinched
2. Module is defective
Corrective Action
1. Locate the fault and repair wires by splicing, soldering, and sealing wires.
2. Contact DICKEY-john Technical Support for a replacement module. See inside,
back cover of this manual for phone number.
ERROR CODE E98 E99
Internal Console Error Contact DICKEY-john Technical Support for further
assistance. See inside, back cover of this manual for phone number.