ERROR CODE E41
Too Many Hopper Sensors are connected to the system.
Probable Cause
Number of Hopper Sensors Configuration is incorrect
Corrective Action
Check the Number of Hopper Sensors Configuration in SETUP MODE with the
actual number of Hopper Sensors connected.
ERROR CODE E50
Too Few Pressure Sensors are connected to the system.
Probable Cause
1. Number of Pressure Sensors Configuration is incorrect
2. Pressure Sensors are failed
3. Implement Harness is not connected to all Pressure sensors
4. Harnessing cut and/or pinched
Corrective Action
1. Check the Number of Pressure Sensors Configuration in SETUP MODE with
the actual number of Pressure Sensors connected.
2. Contact DICKEY-john Technical Support for a replacement sensor. See inside,
back cover of this manual for phone number.
3. Check harness connection to sensor number that corresponds with the number
in the lower display.
4. Locate the fault and repair wires by splicing, soldering, and sealing wires.
ERROR CODE E51
Too Many Pressure Sensors are connected to the system
Probable Cause
Number of Pressure Sensors configuration is incorrect.
Corrective Action
Check the Number of Pressure Sensors Configuration in SETUP MODE with the
actual number of Pressure Sensors connected.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dickey-John Seed Manager SE and is the answer not in the manual?

Dickey-John Seed Manager SE Specifications

General IconGeneral
BrandDickey-John
ModelSeed Manager SE
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals