DI-5000_DP-5000_DPS-5000 Service Manual Edition 2
130
13.3.5.35 Unit Price Override
141d001: Unit Price Override
0: Inhibit
1: Allow on All Modes
2: Allow on Prepack Only
141d129: Force Unit Price Override
0: No
1: Yes
141d195: PLU Unit Price Override Status
0: Inhibit And Default Disabled
1: Allow And Default Disabled
2: Inhibit And Default Enabled
3: Allow And Default Enabled
13.3.5.36 Unit Price Recalculation
141D126: Threshold For Price Base Switching In Unit Price Re-Calculation (g)
0 – 9999 (default 0080)
141D127: Price Base To Use For Unit Symbol kg For Non Weighed Item
0: /kg
1: /100
2: Price Base Switching Base On Threshold