Specification List SM-110 V1.20 20 December, 2005
9
SPEC
NO.
SPECIFICATION DESCRIPTION SM-100
114 Receipt Logo Printing Status
0 No Print 4 Logo 3
1 Logo 1 5 Logo 4
2 Logo 2 6 Logo 1, 2, 3 and 4
3 Logo 1 and 2
115 Type of Entry for Used by Date and Sell by Date
8
0 By Day 1 By Hour
For NICHII only.
116 Barcode Printing in First Label for Dual Label Printout
8
0 Print 1 No Print
For NICHII only.
117 Zero Minutes Printing
8
0 No Print 1 Print
For NICHII only.
118 Both Price before and after Discount
8
0 Price before and after Discount 1 Price before Discount only
For NICHII only.
119 Unit Symbol Printout in Receipt
9
0 Depend on PLU Programming 2 No Print
1 Japanese PCS
For AA only.
120 PLU Number Print
9
0 No Zero Suppress 1 Zero Suppress
121 Thick Japanese Character Printout
8
0 Thick Character 1 Thin Character
For AA only.
122 Prepare Mode after Power On
8
0 Manual Mode 1 Prepack Mode
Always set to 0 for SM-
200.
123 Printing Thank You Message on Receipt
8
0 Enable 1 Disable
124 PLU Unit Price after Discount
9
0 Unit Price after Discount 1 Unit Price Discount Amount
125 Position of Special Message on Receipt
9
0 Bottom 1 Top
126 Function Keys Protection for Self-service
8
0 No Protection 2 Partial Protection
1 Full Protection
127 Printing of Checksum for Item Barcode
0 Disable 1 Enable
128 Setting of Host Number (For SM-15 Multi-drop)
8
Enter value between 0 to 99
For IR only.
129 Type of Host to be Communicated
8
0 Standalone 2 POS ECR
1 TMR ECR
For IR only.
Use with SPEC128.
130 Selection of Print Item on Prepack Total Label
9
0 Based on Status on Item Label 1 Based on Status on Manual Total
Label
131 Print PLU Setting Quantity in Manual Mode
9
0 No 1 Yes
Effective when SPEC98
= 0.
132 Receipt Total Report
8
0 No 1 Yes For DM only.