17 EVOLUTION 1 SYSTEM MANUAL Issue Issue 1.1 20 Dec 2006
NOTE: THE FOLLOWING CODES ARE SPECIFIC TO EVOLUTION II
ONLY
' " ' 0x22 Minimum Bar Width (Range 3-15 Data matrix 2-15)
Default 5
Q. ESC|STX|Address|`"`|SOH|EOT
R. ESC|STX|Address|`"`|`x`|`y`|EOT
D. ESC|STX|Address|`"`|`x`|`y`|EOT
X. ESC|STX|Address|`"`|ACK|EOT
' .' 0x2e Bleed Compensation (Range 0 - 3) Default 0
Q. ESC|STX|Address|`.`|SOH|EOT
R. ESC|STX|Address|`.`|`x`|`y`|EOT
D. ESC|STX|Address|`.`|`x`|`y`|EOT
X. ESC|STX|Address|`.`|ACK|EOT
' * ' 0x28 Quiet Zone (Range 0 - 150) Default 75
Q. ESC|STX|Address|`*`|SOH|EOT
R. ESC|STX|Address|`*`|`x`|`y`|EOT
D. ESC|STX|Address|`*`|`x`|`y`|EOT
X. ESC|STX|Address|`*`|ACK|EOT
'n' 0x6e Type of Barcode (read only)
Q. ESC|STX|Address|`n`|SOH|EOT
R. ESC|STX|Address|`n`|`x`|`y`|EOT
where
x = number of available barcodes
y = type of barcode
0= CODE39
1= TWO OF FIVE
2= CODE 128B
3= CODE 128C
4= UPCA
5= UPCE
6= EAN8
7= EAN13
8= DATAMATRIX