33
EN
IP2163EN
Display Description
ED - Enabling of diagnostics
Enables periodic saving of data via serial for diagnos-
tic use.
NO - Disabled
01 - Checking virtual encoder (DO NOT USE)
02 - Alarm log
US - Type of C-NO contact use
OF - Contact always open
01 - Courtesy light ( o )
02 - LAMP flashing (230V~)
03 - Gate closed
04 - Gate open
05 - Gate moving
06 - Gate opening
07 - Gate closing
ON - Contact always closed
LU - Setting switch-on time for courtesy light (s).
To enable the parameter, set . It is set
with different intervals of sensitivity.
NO - Disabled
- from 01” to 59” with intervals of 1 second;
- from 1’ to 2’ with intervals of 10 seconds;
- from 2’ to 3’ with intervals of 1 minute;
ON - Permanently ON, switched off with remote control
NOTE: The courtesy light switches on at the start of
each operation.
LG - Setting switch-on time for courtesy light con-
trolled independently. [s]
To enable the parameter, set .
It is set with different intervals of sensitivity.
NO - Disabled
- from 01” to 59” with intervals of 1 second;
- from 1’ to 2’ with intervals of 10 seconds;
- from 2’ to 3’ with intervals of 1 minute;
ON - Switched on and off with remote control.
NOTE: The switching on of the light does not depend
on the start of an operation, but can be commanded
separately using the special remote control key.
7.11.1 Additional AP level parameters that can be configured
(available with enabled)
AP - Advanced Parameters