11
IP2159EN
• Prepare the set-up for fixing the automation to the wall, respecting the measurements shown in the figures above (with refer-
ence to the hinge axis).
• Drill a hole in the door wing, in line with the fixing for the articulated arm.
• If necessary, use the DAB805SE2/SE5/SE7 extensions to increase the X measurement between the automation and the arm fixing points.
Shaft extension X
/ 30
DAB805SE2 50
DAB805SE5 80
DAB805SE7 100
6. Automation with articulated arm.
6.a DAS805PSA
Use the articulated arm for doors that open outwards (as seen from the automation side).
6.b DAB805PSAF (for applications on fire doors)
300
max
~400
107X
Y 335
107X
Shaft extension X
/ 48
DAB805SE5F 98
Arm expansion Y
/ 0-100
DAB805TFL 100-215
DAB805TFS
DAB805TKJ
215-305
Ø16
==
Ingresso cavo
42
Automation preparation and fastening (Left-hand opening)
Left-hand opening
X+16 75
34
31
264 248 35
633
212
1
Cable inlet