In the case of automations with left-hand opening, you must invert the
assembly of the articulated arm as shown in the figure.
4
4
4
4
6.a.2 Assembling the left-hand articulated arm
6.b.1 Fixing the arm DAB805PSAF
A
C
B
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
25 Nm
A
210
min 550
90°
+/-
DAB805TFL
Arm extension kit
DAB805TFS
DAB805TKJ
Move the door manually to check it opens and closes
correctly, without any friction.
With the door closed, fix the arm to the arm support
[A] on the automation.
Fix the bracket [B] to the door wing, forming an angle
of 90°. If necessary, lengthen (using the arm lengthen-
ing kit) or shorten the arm [C].
a
b
21026 44
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
25Nm
A
A
NOTE: open the door slightly and tighten
the screw of the arm support seat [A] at
25Nm (as shown in the figure).
If a torque wrench is not available, use a
hexagon wrench of the type shown in the
figure, gripping it on the long side and
tightening very firmly.

Table of Contents