10. Extension unit DAB905ESE (optional)
There is a command extension card for managing the electric lock / electric strike, function selector, batteries, key selector
switch and night-time closure.
10.1 Commands
Contact Function - Accessory Description
3 4
GND-OIMP
N.O. OUTER SIDE OPENING
Contact for connection of external detection radar.
The closure of the contact activates an opening operation.
NOTE: this command is only active with the COM400MKB-MHB function selector switch.
3
5
GND-O/C
N.O. OPEN/ CLOSE IMPULSE
The closure of the contact activates an opening operation. The door stays open until a
new command is given.
If the door does not receive any command, it closes automatically after 15 minutes of
inactivity.
Automatic closing cannot be adjusted using the HOT trimmer; it is factory-set.
The automatic closing time can be modified from 15 min to endless (∞), setting the precon-
figured parameter 2 as explained in chapter 14.
With the ON/OFF/HOLD OPEN switch, the O/C command is always active except in the
HOLD OPEN Position.
With the program selector COM400MHB/MKB the O/C command usually functions in
BIDIRECTIONAL mode.
If necessary, set the pre-configured parameter 8 as explained in chapter 14, the O/C com-
mand will function in BIDIRECTIONAL / MONO-DIRECTIONAL / DOOR CLOSE mode.
3
6
GND-KEY
N.O. KEY OPENING
The closure of the contact activates an opening operation.
This command is always active, even when the COM400MHB/MKB function selector switch
or ON-OFF-HOLD OPEN switch is installed.
The automatic closure time is set to 5 s when the door is open regardless of HOT trimmer
adjustment.
Can be used for opening from night/CLOSED mode.
DAB905ESA
DAB905ESE
DAB105CU
Torx T10
612345
67 8910
12345
12 345678910111213
Applicare l’etichetta alla morsettiera, facendo attenzione al senso di
applicazione (vedi figura sopra).
–
+
12345
ON
KILL
KEY
O/C
OIMP
GND
BATTERIES
12 345678910111213
OPEN
EXIT
OFF
UNL
KRST
Outer side opening
Open/close impulse
Key opening (5s)
Emergency closure
Emergency closure reset
Door released signal
Closed door timer
J
Function selector
–
+
24 V
Electric lock / Electric strike
(12 V max 500mA /24 V max 250mA)
5mm nut
driver
Long pin used for 2 Extension Unit
Short pin use d for 1 Extension Unit only