EasyManua.ls Logo

DITEC DAB105 - Technical Specifications

DITEC DAB105
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
IP2159EN
1. Technical specifications
Ditec DAB105
Power 100-240V~ +10/-15% 50/60 Hz
Consumption max. 75W
Power supply for accessories 24V
400 mA max.
Power supply fuse F1-F2 2xT6.3A 250 V
Opening time min. 3s / 0°-80°
max. 6s / 0°-80°
Closing time min. 3s / 90°-10°
max. 6s / 90°-10°
Door wing opening angle DAB805PSA / DAB805PSAF / DAB805PLA/ DAB808PLAT : 110°
Max. inertia (J / kg
2
)
Inertia J = door weight x (door width)
2
3
DAB805PSA/PSAF: 45kg m
2
DAB805PLA/PLAT: 33 kg m
2
-
50
100
150
200
250
0,7 0,8 0,9 1,0 1,1 1,2
DOOR WEIGHT [kg]
DOOR WIDTH [m]
DAB805PSA/PSAF
DAB805PLA/PLAT
-
1
30 50 70 90 110 130 150 170 190 200
2
3
4
5
6
7
OPSP/CLSP TRIMMER POSITION
DOOR WEIGHT [kg]
OPSP/CLSP TRIMMER
7
4
5
62
3
1
Type of operation Motor opening
Spring-plus-motor closure
Fire barriers Applied using the arm DAB805PSAF
Maximum wing weight
(see inertia graph)
150 kg DAB805PLA/PLAT
200 kg DAB805PSA
Door wing width 700 ÷ 1200 mm (DAB805PLA); 550-1200 mm (DAB805PSA -DAB805PSAF)
Minimum number of manoeuvres in
AVERAGE conditions of use
1,000,000 cycles
Temperature min. -20°C max. +45°C
Degree of protection IP20 (FOR INTERNAL USE ONLY)
DOOR WEIGHT [kg]
DOOR WIDTH [m]
DOOR WEIGHT [kg]
OPSP/CLSP TRIMMER POSITION
OPSP/CLSP TRIMMER

Table of Contents