23.1 DYNAMIC SET-POINT WORKING GRAPHICS
4÷20 ma probe configured as 4..20 mA input
NTC probe with positive differential
NTC probe with negative differential
24. ENERGY SAVING FROM ID FUNCTION
The ES request is active:
If one of the digital inputs configured as ES is active
25. ENERGY SAVING FUNCTION AND TIMED SWITCH-ON AND SWITCH-OFF
1. The ES request with times is active:
2. with three time periods if ES01 / ES06 are different to zero or ES01/ES06 do not have the same value.
25.1 ENABLES THE DAILY/WEEKLY WORKING IN ENERGY SAVING AND AUTOMATIC SWITCH-
ON/OFF MODE
Enter parameters programming:
1. select the parameter ES07 using UP or DOWN (Monday) lower display, upper display 0 - 0 (energy
saving function /switch-on/off disabled). Press SET in the upper display 0 - 0 flashing with UP or DOWN
keys. Set enabling with the time period/s and press SET again to confirm
2. repeat the same operation with the other days of the week ( ES08 / ES13 )
ES14 Increase energy saving set in cooling mode
ES15 Energy saving differential in cooling mode
ES16 Increase energy saving set in heating mode
ES17 Energy saving differential in heating mode