Allows maintenance of the circuit
Allows "partialised" working of the unit
Possibility of enabling/disabling the individual compressor
Maintenance of the individual compressor
Malfunction
Complete management of pump down function:
With dedicated pressure switch
Timed
Via the low pressure switch
Via the low pressure transducer
Circuit unloading function:
From evaporator inlet high water temperature
From condenser inlet high water temperature (unit with heat recovery) Not Available
From high condensing pressure
From low evaporating pressure
Controlled loads maintenance signal function:
Compressors
Evaporator pumps
Condenser pump
Circuit auxiliary relay function:
Four completely configurable relay outputs, also released from normal working of the unit controlled,
managed by means of NTC or PTC temperature probes or with 4÷20mA 0.5 Volt pressure transducer
Weekly working in energy saving mode:
Up to three daily time bands (devices with RTC option)
From digital input
Weekly working with automatic switch on and switch off:
Up to three daily time bands (devices with RTC option)
Dynamic set-point function:
Managed by NTC or 4÷20mA input
Changeover function:
Automatic changeover between cooling and heating by NTC input
Remote OFF function:
From configurable digital input
Remote heating cooling function:
From digital input with configurable logic
Hot start function:
Air/air unit
Defrost management:
In temperature in pressure or with both (combined control)
Forced defrost for start-up with low external air temperatures
From digital input or timed
Manual using the relevant key
Boiler function:
With integration heaters
2 outputs for the proportional control of the condensing fan speeds via external module (inverter
or single/three phase phase cut) with configurable signal:
PWM
0÷10 Volt
4÷20 mA
N° 6 outputs for 0÷10V proportional or ON/OFF control
To control the servomotors working in free cooling or heat recovery mode
For driving an external relay
Complete alarms management
With internal data logger alarms (up to 100 events)
Up to n° 2 programmable remote LCD terminals with customisable values display
with NTC probe on board for room temperature display and temperature control (Not Available).
Supervision/tele-assistance/remote monitoring for complete control and supervision from local and
remote
By means of network output with ModBus TCP / IP protocol (INTERNET / INTRANET)
Directly by telephone line (MODEL WITH INTERNAL MODEM)
Indirectly by means of GSM modem or XWEB serial modem (MODEL WITH RS232 OUTPUT
PREPARATION)