Simga2N Traction Advanced Manual– V1.3 Page 119 (166) ©2021 DMC GmbH Herten Germany
M6-9 BDI warning level ”BDIwarn”
This sets the level of battery voltage at which the BDI warning icon on the Sigmagauge and DMC Display will
start to flash.
The value is set as a percentage, where 100% corresponds to parameter “M6-7 BDI reset level “BDIreset”” and
0% corresponds to parameter “M6-8 BDI empty level “BDIempty””.
The calibrator displays the BDI warning condition in “Menu 0 “Status””.
M6-10 BDI cutout level “BDIcut”
This parameter has a different effect between traction and pump software and can be disabled by setting it to
0.
In traction software, this sets the level of battery voltage at which the speed of the vehicle will be limited to a
value set by the parameter “M6-11 BDI speed limit “BDIspeed””.
The value is set as a percentage, where 100% corresponds to parameter “M6-7 BDI reset level “BDIreset”” and
0% corresponds to parameter “M6-8 BDI empty level “BDIempty””.
The calibrator displays the BDI cut condition in the “Menu 0 “Status”” at lines 2 (F03) and line 3 (BDI value
and BDI status), by pressing + or – buttons.
M6-11 BDI speed limit “BDIspeed”
This set is active only for traction software.
This sets the maximum speed of the vehicle if the BDI level is below the value set by the parameter “M6-10 BDI
cutout level “BDIcut””.
M6-12 Maximum BMS temperature “MaxBattT”
This parameter defines the maximum battery temperature allowed. It used for scaling the battery temperature
bargraph on the DMC Display. It only has to be configured in the DMC Sigma2N Controller with parameter “M6-
2 BMS master controller “BMS Mast”” set to 1.
Notice that only custom displays have the capability to display the BMS temperature. Refer to DMC for
customization request
M6-13 Minimum BMS temperature “MinBattT”
This parameter defines the maximum battery temperature allowed. It used for scaling the battery temperature
bargraph on the DMC Display. It only has to be configured in the DMC Sigma2N Controller with parameter “M6-
2 BMS master controller “BMS Mast”” set to 1.
Notice that only custom displays have the capability to display the BMS temperature. Refer to DMC for
customization request