Simga2N Traction Advanced Manual– V1.3 Page 67 (166) ©2021 DMC GmbH Herten Germany
M1.7-4 Analogue Input 2 maximum voltage level “AI2 max”
This adjustment is active if “M2-9 Analog Input 2 configuration “AI2Cfg”” set to greater than 0. In this way, the
AI2 is configured to work as an analogue torque or speed limit.
• If the input is configured as “Analogue torque limit” (“M2-9 Analog Input 2 configuration “AI2Cfg””
set to 1), this sets the voltage on the analogue input 2 that will correspond to 100% drive torque limit.
• If the input is configured as “Analogue speed limit” (“M2-9 Analog Input 2 configuration “AI2Cfg”” set
to 2 or 3), this sets the voltage on the analogue input 2 that will correspond to a speed limit equal to
”Maximum motor frequency” (adjustable in “Menu 3 “Autotuning””) or to the maximum speed limit
active.
For tuning this parameter refer to “APPENDIX C – Analogue Input tuning”.