M1.7-4 Analogue Input 2 maximum voltage level “AI2 max”
This adjustment is active if “M2-9 Analog Input 2 configuration “AI2Cfg”” set to greater than 0. In this way, the
AI2 is configured to work as an analogue torque or speed limit.
If the input is configured as Analogue torque limit (“M2-9 Analog Input 2 configuration AI2Cfg”
set to 1), this sets the voltage on the analogue input 2 that will correspond to 100% drive torque limit.
If the input is configured as Analogue speed limit” (“M2-9 Analog Input 2 configuration “AI2Cfg”” set
to 2 or 3), this sets the voltage on the analogue input 2 that will correspond to a speed limit equal to
Maximum motor frequency (adjustable in “Menu 3 “Autotuning””) or to the maximum speed limit
active.
For tuning this parameter refer to “APPENDIX C Analogue Input tuning”.