EasyManua.ls Logo

DMC Sigma2N - Page 81

DMC Sigma2N
166 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Simga2N Traction Advanced Manual V1.3 Page 81 (166) ©2021 DMC GmbH Herten Germany
They define the corresponding ramp times and torque levels for the different situations (driving and
neutral/foot/direction braking) when the switches connected to inputs 5 and 6 are configured to select Drive
Style 2 (refer to Control set up M2-3Digital input 5 and 6 configuration Sp/In/Ad”” for configuration details).

Table of Contents

Related product manuals