Simga2N Traction Advanced Manual– V1.3 Page 81 (166) ©2021 DMC GmbH Herten Germany
They define the corresponding ramp times and torque levels for the different situations (driving and
neutral/foot/direction braking) when the switches connected to inputs 5 and 6 are configured to select Drive
Style 2 (refer to Control set up “M2-3Digital input 5 and 6 configuration ”Sp/In/Ad”” for configuration details).