Compliance
29
XR2400F Installation Guide
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
UL 1635 SPECIFICATIONS
Digital Burglar Alarm Communicator System Units
28.1 System trouble display
The Status List Display must include at least one keypad that displays system monitor troubles. See section
10.1 of the XR200 and XR2400F Programming Guide (LT-0196).
28.2 Digital Dialer telephone number
Both programmed telephone numbers must begin with a D or P. See sections 3.17 and 3.18 of the XR200 and
XR2400F Programming Guide (LT-0196).
28.3 Entry delay
The maximum entry delay used must not be more than 60 seconds. See section 7.3 of the XR200 and XR2400F
Programming Guide (LT-0196).
28.4 Exit delay
The maximum exit delay used must not be more than 60 seconds. See section 12.4 of the XR200 and XR2400F
Programming Guide (LT-0196).
28.5 Test time
The Test Time option must be programmed so that the XR2400F sends a report once every 24 hours. See
sections 3.8 to 3.10 of the Programming Guide (LT-0196).
28.6 Closing wait
The Closing Wait option must be programmed YES. See section 7.2 of the Programming Guide (LT-0196).
UL 365 AND 609 SPECIFICATIONS
Police Station Connected and Local Burglar Alarm Units and Systems
29.1 System trouble display
The Status List Display must include at least one keypad that displays system monitor troubles. See section
10.3 of the Programming Guide (LT-0196).
29.2 Grade A bell
A Grade A local audible signal appliance must be used.
29.3 Bell cutoff
The Bell Cutoff time cannot be less than 15 minutes. See section 8.2 of the Programming Guide (LT-0196).
29.4 Automatic bell test
The Automatic Bell Test option must be programmed as YES. See section 8.3 of the Programming Guide.
29.5 Line security for Police Connect
Basic line security is provided when the Model XR2400F is configured as a dialer system.
29.6 High Line Security
High Line Security is provided when configured as a MPX, DNET, or HST system. When HST communication is
used, a dialer line must also be used along with the Model 893 Dual Phone Line Module to supervise the dialer
line. The HST Check-in time must be set from 01 to 06 minutes or AA. See section AA Network
Communication (27.5). Also see sections 3.2, 3.2.1, and 3.3 of the XR200 Programming Guide (LT-0196).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR2400F and is the answer not in the manual?

DMP Electronics XR2400F Specifications

General IconGeneral
BrandDMP Electronics
ModelXR2400F
CategoryControl Panel
LanguageEnglish

Related product manuals