19
ED100LE 02-2021DL4616-001
dormakaba ED100LE operator – Fine cover
Installation Instructions
Chapter 7
Axle extension
EDLE A B C D
Inches mm Inches mm Inches mm Inches mm
Standard ● / / /
/" [] ● / / / /
/" [] ● / / /
Fig. 7.1.5 Assembly on opposite hinge side, with deep push arm assembly
B
D
C
A
Lower edge frame
Lower edge frame
Standard push arm = 0 - 11/13/16” [0 – 300 mm]
Space for cable feed
Note lever
position!
1 1/4”
[32]
9 7/8”
[250]
8 1/8”
[206]
3 15/16”
[100]
4 3/4”
[120]
4 3/4”
[120]
4 3/4”
[120]
3 3/4”
[95]
2 1/2”
[63]
1 3/4”
[45]
Ø 1/4”
[6,6]
1 5/16
[33]
1 31/32
[50]
12 13/16”
[325]
5 11/16”
[145]
Deep push arm = 0 – 19 5/8” [0 – 500]