50
WN 059677 45532 - 11/2023
ES 250 PRO/ES 250 PRO FST
ES 400 PRO/ES 400 PRO FST
Mounting instructions
5.2.1 CANBUS Y-adapter
• A CANBUS Y-adapter is used to install branches in a CAN BUS system.
• Only 1CANBUS component may be connected to a branch.
• Up to 5branches may be installed in a CAN BUS system.
• The cable length on a branch may be no more than 10m.
Fig.81
5.2.2 STPRO multi-point locking system
The STPRO multi-point locking system interrupts the CAN BUS connection during
operation. Therefore, the STPRO multi-point locking system must be connected to
the CAN BUS system using a CANBUS Y-adapter.
Attention
The extension cable may not be used for the STPRO multi-point
locking system!