65
WN 059677 45532 - 11/2023
ES 250 PRO/ES 250 PRO FST
ES 400 PRO/ES 400 PRO FST
Mounting instructions
10 Fire protection function
The fire protection function enables the sliding door to close safely in case of fire.
The function is controlled externally, e.g. via fire alarm systems or building
management systems. A rechargeable battery is required for the function.
Note
The fire protection function is not available for the FST operator.
10.1 Activate the fire protection function
1. Connect the external control unit for the fire protection function to the
multiport or the EMI/O.
2. Activate the fire protection function via the "P" parameter.
3. Configure the multiport for fire protection.
When the parameter "P" is set to the fire protection function, the following
functions/parameters are changed:
Parameter Is changed to
Can be changed
subsequently
Obstacles in Open 5 yes
Obstacles in Closed 5 yes
Blocking function Door stops yes
Night/bank configuration Edge no
Battery mode
Emergency
operation
no
Power saving mode is ignored no
Emergency switch CAN function momentary function no
Waiting time at the obstacle in closing
direction
5 seconds no
When the fire protection function is triggered, the door closes and is locked.
The door moves at creep speed due to the deactivated sensor system.
The following functions are no longer possible:
Opening the door via the sensor system
Change of the operating mode
Fire brigade functionality
Panic lock
Close dead man’s switch
Open dead man’s switch
Pharmacy functionality
Opening the door is now only possible via emergency opening or the night/bank
impulse.